2010
The International Symposium on New Refrigerants and Environmental Technology 2010
Latest Technology of Energy Conservation, New Refrigerants and Environment issue on Air conditioning and Refrigeration Equipment including Automotive A/C for lead up to the 21st Century
December 2 (Thursday) - 3 (Friday), 2010
Shigeharu Minagawa, Deputy Director, Ozone Layer Protection Policy Office, Ministry of Economy, Trade and Industry, Japan |
Stephen R. Yurek, President and CEO, The Air-Conditioning, Heating, and. Refrigeration Institute, U.S.A. |
Motoshi Matsushita, Sharp Corporation, Japan |
Advanced Switch between Sensorless Sinusoidal Wave Drive and Rectangular Wave Drive for Performance Optimization in Air-Conditioner Compressor |
Ryuji Kitano, Toshiba Carrier Corporation, Japan |
Technology of Energy-saving and Cost Reduction on Heat Exchanger for Air Conditioner |
Yasuhide Hayamaru, Mitsubishi Electric Corporation, Japan |
Energy Saving by Room Air Conditioner |
Satoshi Nikaido, Mitsubishi Heavy Industries, Ltd., Japan |
Optimal Control Method of Heat Source System with Centrifugal Chillers |
Akihiro Takeuchi , Toshiba appliance Corporation, Japan |
Evaluation of Energy Efficiency of Air-Conditioner with Dual Compressor at low load |
Yukisige Shiraichi , Sharp Corporation, Japan |
Effects of Air-Conditioner with an Enveloping-Airflow on Sense of Fatigue and Comfort |
Akimasa Yokoyama, Mitsubishi Heavy Industries, Ltd., Japan |
Variable speed centrifugal chiller with optimal control for independent two refrigerant circuits |
Andrea Voigt, European Partnership for Energy and the Environment(EPEE), Belgium |
The European Context - An Overview of Current and Upcoming EU Legislation for the HVACR Sector - |
Masato Sakui, Environmental Planning Committee, JRAIA, Japan Susumu Ishii, JARAC, Japan |
JRAIA and JARAC Established Guideline for Prevention of Refrigerants Emission |
Norihiro Itsubo, Tokyo City University, Japan |
LCA Comparison of Refrigerant Reclamation and Destruction Applying LIME Method |
Manabu Yoshimi, Daikin Industries Co., Ltd., Japan |
The State of the Art Remote Refrigerant Leak Detection System for Variable Refrigerant Volume Air Conditioners |
Takeshi Ishii, Sanyo Electric Co., Ltd., Japan |
The development of refrigerant leakage detection system for commercial refrigeration |
Masahide Sumi, Asada Corporation , Japan |
Latest Refrigerant Leak Detection Technology and Effective Leak Prevention Measure |
Michiyuki Saikawa, Central Research Institute of Electric Power Industry, Japan |
Role and Challenges of Electric Driven Compression Heat Pump |
Kimitaka Kadowaki, Mayekawa Mfg. Co., Ltd., Japan |
Development of a Kiln Dried Wood System using CO2 Heat Pump Technology |
Tomikazu Usumoto, Heat Pump Technology Study Group, JRAIA, Japan |
Consideration of Heat Pump Technology |
Ryo Ohta, Hitachi, Ltd. Materials Research Laboratory, Japan |
Properties of Refrigerant / Oil Mixture for Low GWP Refrigerants |
Tatsuya Sasaki, Mitsubishi Electric Corporation, Japan |
Tribology Characteristics of HFO and HC Refrigerants with Immiscible Oils - Effect of Refrigerant with Unsaturated bond |
Atsushi Sakuda, Home Appliances Company, Panasonic Corporation, Japan |
Development of the clearance control technology for CO2 scroll compressor |
Masatsugu Chikano, Hitachi, Ltd., Japan |
Visualization of Flow in Scroll Compressor by Radiography |
Giacomo Pisano, DORIN S.p.A (DORIN on behalf of ASERCOM), Italy |
Energy Efficiency and Natural Refrigerants: European Trends relating to RAC Compressor Industry |
Rikako Nakamura, Japan Sun Oil Company, Ltd., Japan |
Development of compressor oils for the future refrigerant, HFO-1234yf - Study of chemical stability test - |
Joe Karnaz, CPI Engineering Services, Inc., / Lubrizol, U.S.A. |
Lubricants for Low GWP Refrigerants |
Tomoya Matsumoto, Idemitsu Kosan Co., Ltd, Japan |
Evaluation of Various Lubricants for a low Global Warming Potential (GWP) Refrigeration System |
Takeshi Okido, JX Nippon Oil & Energy Corporation, Japan |
Development of refrigeration oils for next generation low GWP refrigerants |
Harry Eustice, General Motors Corporation, U.S.A. |
A Vehicle Manufacturer’s Perspective on alternative Refrigerant Development |
Yoshiaki Takano, Denso Corporation, Japan |
Ejector System for Passenger Vehicle Air-conditioners |
Takeshi Ogasawara, Calsonickansei Corporation, Japan |
Heat pump air conditioning System introduction for EV |
Takehiro Hasegawa, Sanden Corporation, Japan |
Introduction of Hybrid Compressor and Inverter for Control |
Thomas J. Leck, DuPont Fluoroproducts, U.S.A. |
Development and Evaluation of Reduced GWP AC and Heating Fluids |
Samuel F. Yana Motta, Honeywell, U.S.A. |
Latest Developments in Low Global Warming Refrigerants for AC&R |
Kenji Takizawa, National Institute of Advanced Industrial Science and Technology (AIST), Japan |
Burning velocities of mildly flammable low GWP refrigerants |
Zhang Zhaohui, China Refrigeration and Air Conditioning Industry Association (CRAA) , China |
Introduction to HCFCs Phase-Out Progress in China Industrial and Commercial Refrigeration and Air-Conditioning Sector |
Shigeharu Taira, Daikin Industries Co., Ltd., Japan |
Evaluation and Practical Use of Equipment Using New Refrigerant as an Urgent Countermeasure against Global Warming |
Thomas J. Leck, DuPont Fluoroproducts, U.S.A. and, Fuji Electric Retail Systems Co., Ltd., Japan |
HFO-1234yf Performance in a Vending Machine |
Kei Kawasaki and Hitoshi Asano, Kobe University |
Boiling Heat Transfer Enhancement by Thermal Spray Coating |
Yoji Onaka, Akio Miyara and Koutaro Tsubaki, Saga University, Japan Shigeru Koyama, Kyusyu University, Japan |
Analysis of Heat Pump Cycle Using Refrigerant Mixture |
Koutaro Tsubaki, Akio Miyara and Nobuki Sato, Saga University, Japan |
Measurement of the Thermal Conductivity of HFO-1234ZE(E)+HFC32 Mixture Refrigerant |
Lei Gao, Wataru Hamada, Yoshihiro Watanabe and Tomohiro Honda, Fukuoka University, Japan Ryusuke Takigawa and Takao Shimizu, Chino Corporation, Japan |
Measurement of Oil Circulation Ratio in CO2 Heat Pump Systems |
Lei Gao, Wataru Hamada, Yoshihiko Watanabe and Tomohiro Honda, Fukuoka University, Japan |
Measurement of Flow Boiling Heat Transfer Coefficient of CO2-Oil Mixture Inside a Cupper Tubes Using Electrical Resistance Method |
Naoyuki Yada, Hiroyoshi Hosomura, Yutaka Ohtsu and Yuki Horikoshi, KANAGAWA Institute of Technology, Japan |
Examination of Performances for HC Refrigerant Mixtures (NECO) in Domestic Air-Conditioner Systems |
Takeshi Yamazaki, Coucou Thin, Takayuki Masuda, Nozomu Watanabe and Naoyuki Yada, KANAGAWA Institute of Technology, Japan |
A Study by Thermodynamic Properties for HC Refrigerant Mixtures (NECO) |
Shigeru Koyama, Nobuo Takada and Sho Fukuda, Kyushu University, Japan |
An Experimental Study on the Performance of Heat Pump Cycle Using Refrigerant Mixtures of HFO-1234ze(E) and HFC-32 |
Hidemitsu Nakamura, Industrial Network for Fluorocarbon Recovery Promotion (INFREP), Japan |
Activities for Fluorocarbons Recovery Promotion on Commercial Refrigeration & Air-conditioning Units |
Ikuhide Ota, Ammonia AC/R system promotion sub Committee, JRAIA, Japan |
Promotion Activity Primary Training Course, Promotion Pamphlets for Ammonia System |
Makoto Kimura, Sanden Corporation, Japan |
Examination of LGWP Refrigerant for Cooling Show Case |
Issei Higami, Dengen Co., Ltd., Japan |
Development of A/C tools applied in HFO-1234yf |
Kotaro Matsu, Tokyo Braze Co., Ltd., Japan |
Development of High Pressure Resistance Plate Heat Exchangers Applicable to Carbon Dioxide (CO2) Refrigerant |
Matthias Seiler, Marc-Christoph Schneider, Oliver Zehnacker and Rolf Schneider, Evonik Degussa GmbH, Germany |
Ionic Liquids: New High-Performance Working Fluids for Absorption Chiller and Heat Pumps |
Shigeru Suwa, Pro-Step co, Ltd., Japan |
"Two in One" Refrigerant Recovery & Recharging Unit, Can Be Used for Two Deferent Types of Car Air-Conditioning Systems, (EV, HV) and (Gas, Diesel) |
Environmental Committee, JRAIA, Japan |
CO2 Equivalent Labeling of Refrigerants |